plan9front_-_plan_9_instance_under_xen
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revision | |||
plan9front_-_plan_9_instance_under_xen [2024/01/12 06:15] – [Shutdown and restart] ]] m( hc9 | plan9front_-_plan_9_instance_under_xen [2024/09/07 06:41] (current) – ''’ hc9 | ||
---|---|---|---|
Line 60: | Line 60: | ||
=== Install === | === Install === | ||
- | After receiving notification of an allocated VPS slice, connect by ''' | + | After receiving notification of an allocated VPS slice, connect by ‘'' |
< | < | ||
Line 86: | Line 85: | ||
</ | </ | ||
- | |x|Press the '[**Enter**]' | + | |x|Press the ‘[**Enter**]’ key to continue to the [[# |
You will now [[: | You will now [[: | ||
Line 93: | Line 92: | ||
|x|**ctl-h** is backspace, kind of; **ctl-u** erases the current line. As seen, with the VPS Plan 9 console prompt **ctl-h** backspace, the screen output may not be what one would expect.| | |x|**ctl-h** is backspace, kind of; **ctl-u** erases the current line. As seen, with the VPS Plan 9 console prompt **ctl-h** backspace, the screen output may not be what one would expect.| | ||
- | |x|To detach the Plan 9 console prompt (%), while retaining the ability to reattach it __without__ rebooting your server, press **ctl-]** to close the prompt (%). Then, press '**q**' | + | |x|To detach the Plan 9 console prompt (%), while retaining the ability to reattach it __without__ rebooting your server, press **ctl-]** to close the prompt (%). Then, press ‘**q**’ to disconnect the VPS Maintenance Shell menu, and ssh connection. You can return again with another [[# |
|Plan 9 Rc shell|[[: | |Plan 9 Rc shell|[[: | ||
Line 122: | Line 121: | ||
|x|This [[# | |x|This [[# | ||
- | < | + | < |
===== Shutdown and restart ===== | ===== Shutdown and restart ===== | ||
Line 161: | Line 160: | ||
</ | </ | ||
- | |x|'' | + | |x|'' |
=== From the 9front VPS Maintenance Shell console prompt: === | === From the 9front VPS Maintenance Shell console prompt: === | ||
Line 175: | Line 174: | ||
</ | </ | ||
- | |1|Press **ctl-]** to continue, if viewing where the VPS console rc prompt (%) was once active. Press the '[**Enter**]' | + | |1|Press **ctl-]** to continue, if viewing where the VPS console rc prompt (%) was once active. Press the ‘[**Enter**]’ key to access the VPS Maintenance Shell (may apply).| |
- | |x|From the VPS Maintenance Shell enter '**s**' | + | |x|From the VPS Maintenance Shell enter ‘**s**’ - force shutdown, then enter ‘**r**’ - reset or start, or ‘**q**’ - disconnect. Enter ‘**l**’ to list your status.| |
- | |x|From the VPS Maintenance Shell enter '**s**' | + | |x|From the VPS Maintenance Shell enter ‘**s**’ - force shutdown before starting the SDF 9front VPS. Ping the SDF Plan 9 VPS IP address ([[: |
< | < |
plan9front_-_plan_9_instance_under_xen.1705040141.txt.gz · Last modified: 2024/01/12 06:15 by hc9